| SI. No |
Building Rule No |
Description |
Minimum Requirement |
1 (a) |
5(2)(a) |
Building Accessible to
a)Low Tension electric Line b)High Tension electric Line Building not Accessible to
a)Low Tension electric Lines b)High Tension electric Lines |
Horizontal Clearance |
Vertical Clearance |
1.50 m 1.75 m
5(2)(a)
1.25 m 1.25 m |
4.50 m 4.50 m
5(2)(c)
2.50 m 2.50 m |
| 1 (b) |
5(4) |
Building should be away from the Railway land boundary |
30 m |
| 2(a) |
6(1) |
Minimum width of site for dwelling Minimum extent of site for dwelling |
6 m 90 Sq.m. |
| 2(b) |
6(4) |
For constructing Prayer hall or Building for Religious purpose |
Prior Permission from the District collector should be obtained |
| 2(c) |
6(5) |
Clearance from the Burial ground for dwelling purpose building |
90 m |
| 3 |
7 |
Clearance from the Water resources like reservoir, well, channel, river, pond |
15 m |
| 4 |
9 |
Height of basement from existing ground level for the buildings |
45 cm |
| 5(a) |
11 (2)(a) |
Building line from the road edge i.e. Front open space |
1.30 |
| 5(b) |
11(3) |
Permissible height of building 1.5 times abutting road width + Minimum front open space 1.30 m + 1 m for every 0.3 m space left for front open (which excludes 1.30 m) EXAMPLE:
DETAILS OF SKETCH: 1. Road Width = 10 m * 1.5 Times = 15 m 2. Minimum Front Open Space---- = 1.3 m 3. 1 m for every 0.3 m - - - - - - - -= 2.0 m (excluding 1.3 m front open)
| |
|
| Total Permissible Height = |
|
18.30 m |
| |
|
|
|
| 5(c) |
11(4) |
Space kept as open to sky for buildings for dwelling |
1/4 th area of total area of the plot |
| 7(a) |
13(1)(a) |
Height of roof from the floor for Habitable room, excluding kitchen, bath and store |
2.75 m |
| (b) |
13(1)(b) |
Minimum extent of habitable room |
7.50 Sq. m. |
| (c) |
13(1)(c) |
Minimum Width of habitable room |
2.50 m |
| (d) |
13(2) |
Minimum Extent For bath Room For Water closet For combined "Bath & WC" or "Toilet" |
1.50 m * 1.20 m 0.90 m * 1.20 m 1.50 m * 1.80 m |
| 8 (a) |
14(1) |
Minimum ventilation space for every habitable room |
1/8 th floor area of the room |
| (b) |
14(2) |
Ventilation adjoining corridor Width of corridor maximum 3.75 m width with fully opened and abutting an open space of twice the width of corridor or minimum of 1.75 m
|
|
| (c) |
14 (3) |
Window or Ventilator should be abutting an open space area |
2.50 m * 1.75 m open space |
| (d) |
14(6) |
Laboratories and bath rooms should have windows and Ventilators of not less than 0.5 Sq.m. abutting open space area |
1.75 m * 2.5 m open space |
| 9(a) |
15(2)(c) |
Stair case steps Maximum Height of steps (rise) Maximum Width of steps (tread) |
17.5 cm (max.) 25.0 cm (max.) |
| (b) |
15(3) |
Minimum width of Door opening Entrance & Exit of Room Kitchen, Bath, Toilet door width Passage |
1.0 m (min) 0.6 m (min) 0.75 m (min) |
| 10 |
17 |
Sufficient arrangements should be made for the drainage of storm water, Sewage from the premises |
|
| 11 |
|
Rain water harvesting arrangements should be made in the premises |
|